- Describe the purpose of a fluid power system
 - Differentiate between fluid power systems and mechanical or electrical systems
 - Differentiate between hydraulic and pneumatic systems with respect to the fluid medium employed, characteristics, capacity, performance, and cleanliness
 - Describe a basic fluid power system in terms of power conversion.
 - Draw the schematic symbol for a motor and internal combustion engine.
 - Describe the role of a pump in a fluid power system. Draw the schematic symbol for a pump and reservoir.
 - Describe what properties pressure, flow rate, and valve position influence in a fluid power system.
 - Describe Pascal’s Law and the formula used to relate force, pressure, and area.
 - Describe the role of an actuator in a fluid power system. Draw the schematic symbol for a cylinder and hydraulic motor.
 - Comment on the drawbacks of systems composed of numerous stages
 - Comment on the advantages and disadvantages of fluid power systems
 - Identify safety concerns associated with fluid power systems.
 - Comment on sources of inefficiency within a fluid power system
 - Identify five different types of pressure control valves
 - Draw the schematic symbol for a pressure gauge, pressure switch, and pressure transducer
 - List the devices that control flow rate
 - Draw the schematic symbol for a flow control valve and comment on how they are employed in fluid power systems.
 - Draw the schematic symbol for flow meters and comment on how they are employed in fluid power systems.
 - Draw the schematic symbol for a check valve. Differentiate between free flow and blocked direction.
 - Describe the purpose of a directional control valve in a fluid power system.
 - Draw the schematic symbol for a 3 position, spring centered, manually actuated directional control valve with a closed center, a straight through position, and a cross connect position
 - Discuss how the above valve’s position influences a double acting cylinder’s actuation direction when the cap end port is hooked to actuator port A and rod end port is hooked to actuator port B.
 - Discuss how the above valve’s position influences a double acting cylinder’s actuation direction when the actuator ports are swapped (rod end port is hooked to actuator port A and cap end port is hooked to actuator port B).
 - Discuss how a double acting cylinder’s actuation direction is influenced when one port is blocked.
 - Describe the purpose of mechanical limit switches, magnetic proximity switches, and position transducers in a fluid power system.
 - Differentiate between energy and power and give examples of common energy and power units.
 - Determine the energy requirement in ft*lbf to move a 500lbf object 12ft.
 - Determine the power requirement in ft*lbf/s, hp, and W to move a 500lbf object 12ft in 2.3s.
 - Given a 72% efficient system determine the input power in W necessary to produce 5.6hp output
 - Given a 79% efficient system determine the output power in hp if 3.2kW was input
 